General Service Pressure Gauges (101P Series)
Standard Specification Overview
Dial Size
40mm (1.5″), 50mm (2″), 60mm (2.5″), 75mm (3″), 100mm (4″), 150mm (6″), 200mm (8″)
Reference Accuracy
- 40mm : ± 3.0% of Full Scale
- 50mm, 60mm, 75mm : ± 1.5% of Full Scale
- 100mm, 150mm, 200mm : ± 1.5% of Full Scale
Scale Ranges
- 40mm:0~0.2to0~3.5MPa
- 50mm:Vacuum,0~0.1to0~5.0MPa
- 60mm,75mm:Vacuum,Compound&0~0.1to0~25MPa
- 100mm, 150mm : Vacuum, Compound & 0 ~ 100 MPa
- 200mm : Vacuum, Compound & 0 ~ 100 MPa
* For more information, see the ordering information table.
Standard Process Connection
- 40mm : PT (“R” in ISO) 1/8”, 1/4”
- 50mm, 60mm : PT (“R” in ISO) 1/4″
- 75mm : PT (“R” in ISO) 3/8″
- 100mm : PT (“R” in ISO) 3/8”, 1/2”
- 150mm, 200mm : PT (“R” in ISO) 3/8″
* No throttling screw inserted in the pressure port.
Material
- Case : Black Finished Steel
- Ring (Cover) : Black Finished Steel
- Window : Glass
- Pointer : Aluminum Alloy, Black Finished
- Connection : Brass
- Element (Bourdon Tube) : Brass
- Movement : Brass
- Dial Plate : White Aluminum with Black Graduations
Optional Extra
- Test Report by Manufacturer
- Test Report by KOLAS (ILAC-MRA)
- Polycarbonate Case & Cover (only for 60 & 100mm) · Cleaning Service (USE NO OIL)
- Throttling Screw (Restriction Orifice)
Applications
- Non-corrosive gas, air, oil and water
- Pneumatics
- Vacuum equipment
- Visual Montoring of air and gas pressure for compressors · Heating, ventilation, climate
- Pumps and regulators
- Medical gas cylinders
- Media not attack to brass
Pressure Limitation
- Steady : 3/4 of full scale value (recommendation : 25% to 75% of full scale)
- Fluctuating : 2/3 of full scale value (recommendation : lower 50% of full scale)
- Short time : full scale value
Operating Temperature
- Ambient : -20 ~ 60°C
- Media (Fluid) : -5 ~ 60°C